Your competent partner for industrial emission monitoring in Asia Pacific sales@twintek.com +(65) 64671512 | 64671553

Incineration

INCINERATION

incineration
Incineration & Incinerator Emissions Monitoring & Analysis

Monitoring of incineration emissions is a demanding application for Continuous Emission Monitoring Systems. Incinerator emissions are highly corrosive, some of the gases are soluble and, because the waste being burnt is constantly changing, the resulting stack gas temperature varies widely. There are several types of Incinerators and Thermal Oxidisers used in a variety of industries and Protea have a wealth of experience in both monitoring emissions and controlling Flue Gas Scrubbing systems, including:

  • Large Domestic Garbage Incinerators
  • Waste to Energy Projects
  • Biohazard & Chemical Industry Incinerators
  • Thermo Oxidisers in the Automotive Industry
  • Chemical & Biological Weapon Destruction
  • Pulp Mill Incinerators
  • Crematoria & Animal Incinerators
Continuous Emission Monitoring

The Protea 2000 in-situ infra-red analyser with heated probe, resists corrosion from the acid gases by keeping the sample gas above the dew point. With integral automatic zero and calibration capability, this instrument presents low installation and maintenance costs. In addition to monitoring the pollutant emissions, the system can be expanded to incorporate Oxygen, Particulate / Opacity and Velocity. This integrated approach to emissions analysis enables, when required, the concentrations to be normalised, reported on a dry basis and in mass measurements.

Gas

Ranges

CO

0 – 25 mg/Nm3

SO

0 – 600 mg/Nm3

NO

0 – 400 mg/Nm3

NOx

0 – 400 mg/Nm3

H2O

0 – 20%

HCI

0 – 1500 mg/Nm3

HF

0 – 200 mg/Nm3

Scrubber Control

For control of Incinerator flue gas scrubbing systems, Protea 2000 produces very stable HCl measurements in the presence of high levels of water vapour, and its rapid response time makes it an ideal instrument for scrubber control.

The analyser works well in the high dust applications of cement plants and has also been successful in high dust incineration applications.

Gas

Ranges

H2O

0 – 20%

CO

0 – 20%

HCI

0 – 500 mg/Nm3

SO

0 – 800 mg/Nm3

CO

0 – 800 mg/Nm3

Scrubber Control De-NOx

Protea 2000 provides measurements for analysing gases associated with Oxides of Nitrogen removal by Ammonia injection. This de-NOx process, if carried out alongside scrubber measurements using a second analyser, can exploit the multi-analyser control capability of the Protea controller with sophisticated reporting capability.

Gas

Ranges to Suit Process

NH3

0 – 100mg/Nm3

H0

0 – 500mg/Nm3

We offer an innovative range of opacity, dust, particulate and smoke monitors to suit a variety of continuous gas emission applications such as boilers, filter bag houses, incinerators and other industrial processes.

DynOptic opacity monitors use the light transmission technique to measure the visible opacity of exhaust gas in a duct, stack or flue, in which a high intensity light beam is projected across the stack. Click here for more information.

DynOptic dust monitors use the innovative Dynamic Detection Principle (DDP) to measure dust and particulate within exhaust gases from various manufacturing processes. Click here for more information.

DynOptic particulate monitor is an optical instrument designed to measure the concentration of dust or particulate matter in an exhaust gas. When calibrated against standard reference measurement reading as mass concentration [mg/m³]. Click here for more information.

For further information about any of our products please call or e-mail and a member of our team will be happy to help.

Request more info

DSL-220MkIII 400_230

DSL-220MkIII

DSL-220 MkIII – traditional single pass opacity monitor for measuring visible opacity (0 – 100 %) in combustion and air filtration processes.
Read More
DSL-320 MkIII 400_230

DSL-320MkIII

DSL-320 MkIII – classic double pass opacity monitor for measuring visible opacity (0 – 100 %) in combustion and air filtration processes.
Read More
DSL-230MkIII 400_230

DSL-230MkIII

DSL-230 MkIII – conventional single pass particulate monitor for measuring particulate density (mg/m³) in combustion and air filtration processes.
Read More
DSL-330 MkIII 400_230

DSL-330MkIII

DSL-330 MkIII - standard double pass particulate monitor for measuring particulate density (mg/m³) in combustion and air filtration processes.
Read More