Your competent partner for industrial emission monitoring in Asia Pacific sales@twintek.com +(65) 64671512 | 64671553

Power Generation

POWER GENERATION

Power Plant Emissions & Power Station Emissions Monitoring (CEMS)

Oil & gas fired thermal power plants are a mirror of their larger coal fired equivalents although specific emissions limits are often lower. This places demanding requirements on the CEMS analyser in terms of process stress with an additional loading of having to measure at lower absolute levels

Diesel power plants are a frequent choice where rapid economic development outstrips the local grid capacity or remoteness precludes linkage with that grid. Often operating on variable load profile and frequent stop/start conditions, the systems require reliability, as service support will often be a remote resource. 

Example

Coal Fired fitted with Flue Gas De-Desulphurisation (FGD) Scrubber

Gas

Inlet Analyser

Outlet Analyser

Function

SO2

0 – 1,000 ppm

0 – 100 ppm

Control / Reporting

NO

0 – 1,000 ppm

0 – 1,000 ppm

Reporting

CO

0 – 250 ppm

0 – 250 ppm

Control /Reporting

CO2

0 – 15% CO2

0 – 15%

Reporting

H2O

0 – 20%

0 – 20%

Diagnostic / Dry Basis Correction


We offer an innovative range of opacity, dust, particulate and smoke monitors to suit a variety of continuous gas emission applications such as boilers, filter bag houses, incinerators and other industrial processes.

DynOptic opacity monitors use the light transmission technique to measure the visible opacity of exhaust gas in a duct, stack or flue, in which a high intensity light beam is projected across the stack. Click here for more information.

DynOptic dust monitors use the innovative Dynamic Detection Principle (DDP) to measure dust and particulate within exhaust gases from various manufacturing processes. Click here for more information.

DynOptic particulate monitor is an optical instrument designed to measure the concentration of dust or particulate matter in an exhaust gas. When calibrated against standard reference measurement reading as mass concentration [mg/m³]. Click here for more information.

For further information about any of our products please call or e-mail and a member of our team will be happy to help.

Request more info

DSL-220MkIII 400_230

DSL-220MkIII

DSL-220 MkIII – traditional single pass opacity monitor for measuring visible opacity (0 – 100 %) in combustion and air filtration processes.
Read More
DSL-320 MkIII 400_230

DSL-320MkIII

DSL-320 MkIII – classic double pass opacity monitor for measuring visible opacity (0 – 100 %) in combustion and air filtration processes.
Read More
DSL-230MkIII 400_230

DSL-230MkIII

DSL-230 MkIII – conventional single pass particulate monitor for measuring particulate density (mg/m³) in combustion and air filtration processes.
Read More
DSL-330 MkIII 400_230

DSL-330MkIII

DSL-330 MkIII - standard double pass particulate monitor for measuring particulate density (mg/m³) in combustion and air filtration processes.
Read More