TO Multi-Stream Bypass System
A large pharmaceutical plant runs a Thermal Oxidiser on plant to incinerate their solvent-containing gas streams before emission. When the oxidiser is offline, then the plant must monitor the release of solvent to the atmosphere.
A ProtIR 204C fixed monitoring system was installed that continually measures 24 plant solvents, including Acetone, Cyclohexane, DCM, DMF, IPA, MIBK, Toluene and THF. Given the high levels that are possible, the system has an active dilution system, reducing the concentration of the measured gas in the analyser to levels that can be analysed simply. Chemometric modelling enables interferences from the overlapping absorption spectra to be accounted for, ensuring accurate analysis of all 24 gases.
Measurements from the system are fed into a live dispersion model on plant, enabling estimates of ground level concentrations at points around the site to be displayed in real-time.